The Julian Street Inn – Shelter for the Homeless: Building Permit set R of drawings for the “Residential Building” – Framing Plans
27/08/1987Three framing plans with additional explanatory details related to specific wood connections and construction specifications.
Contents
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Framing Plans
27/08/1987
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Framing Plans
27/08/1987
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Framing Plans
27/08/1987
References
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Drawing Index
27/08/1987
Sheet listing the set of drawings for the Residential Building .
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Cross and Longitudinal Sections
27/08/1987
Drawing with two longitudinal and two cross sections as they were revised on 27-Aug-1987.
-
The Julian Street Inn - Shelter for the Homeless: Building Permit set R of drawings for the "Residential Building" - Structural Drawings & Construction Details
27/08/1987
Six structural drawings including: 1) & 2) Cross sections with specifications and detail references; 3) Vertical sections with architectural and structural details; 4) Concrete column details; 5) Concrete beam elevations; 6) Stud wall construction .
SEE ALL Drawings
-
Pasadena Zoning Ordinance for Multi-Family Housing: Minutes of meeting on parking schemes
16/11/1987
Five pages describing the pros and cons between the various proposals presented for the four types of parking and their suggested densities and location: proposals relating to the various lot sizes of the RM-32 & RM-48 zones. Issues also discussed: ...
-
The Julian Street Inn - Shelter for the Homeless: Cost-free clarifications for residential building - Walls
15/08/1988
Four construction clarifications: 1) Specifies the exact wall placement of the two passageways; 2) Specifies the size and placement of the day room street wall; 3 & 4) Specify the second floor’s exterior wall sheathing and nailing spacing.
-
The Julian Street Inn - Shelter for the Homeless: Cost-free clarifications for residential building - Roof & floor sheathing
15/08/1988
Two construction clarifications specifying: 1) The changes in the construction of the 2nd story floor decking; 2) The removal of the 2×4 unnecessary blocking between trusses.