The Julian Street Inn – Shelter for the Homeless: Cost-free clarifications for 1st floor arcade – Beams
04/10/1988Three clarifications focused on the construction of the arcade beams and their various connections and supports: 1) 6″x12″ beam connection at the lobby end of the arcade; 2) 6″x6″ rafter connection to the 6″x12″ beam; 3) All beams of the arcade and their detailed connection to the residential building wall .
Record:
References
-
The Julian Street Inn - Shelter for the Homeless: Building Permit drawings of Set R "Residential Building" - Structural system
2 2) Heavy timber details for ceilings in main lobby and entrance lobby
27/08/1987
Two structural design drawing sheets with detailing of heavy timber elements.
-
The Julian Street Inn - Shelter for the Homeless: Building Permit drawings of Set R "Residential Building" - Structural system
2 2) Exterior staircase plan, section & elevation
10/07/1987
Two structural design drawing sheets.