The Julian Street Inn – Shelter for the Homeless: Open lacework concrete trusses shot in place with gunite: Structural element analysis of truss #2 – Early version

02/04/1987
Design Matters, Calculations

4-page with finite element analysis of hand-calculated load distribution on the joints and frame-members. Two structural sketches depict truss #2, an earlier design idea, forming one full central arch and two half arches at the two ends.

Authors:
Randall Schmidt, Center for Environmental Structure, Berkeley, CA, U.S.A.
References