The Julian Street Inn – Shelter for the Homeless: Open lacework concrete trusses shot in place with gunite: Structural element analysis of truss #2 – Early version
02/04/19874-page with finite element analysis of hand-calculated load distribution on the joints and frame-members. Two structural sketches depict truss #2, an earlier design idea, forming one full central arch and two half arches at the two ends.