The Julian Street Inn – Shelter for the Homeless: Plan Correction Directive
31/10/19877-page official report from the Fire Department on the building permit drawings. It provides a 37-point list with detailed comments and guidelines on specifications and items required to be corrected and furnished.
References
-
The Julian Street Inn - Shelter for the Homeless: Building Permit drawings of set B "Building Complex" - Fire protection
10/07/1987
Fire Protection drawing sheet with floor plans highlighting the sprinklered areas and indicating the fire-resistant walls.
-
The Julian Street Inn - Shelter for the Homeless: Preliminary Design Drawings - Drainage plans
15/04/1987
Two mechanical design drainage plans for the interior courtyards of the building, with handwritten notes and specifications.
-
The Julian Street Inn - Shelter for the Homeless: Construction Drawings MEP - Sprinkler system
04/03/1988
Two mechanical design drawing sheets of the sprinkler system water flow, installed in the building interior spaces and the exterior arcades; drawings include details of the pipe profiles and ceiling attachments, as well as building sections with the vertical layouts.
SEE ALL Drawings